News arrow Products arrow S7 Adapter arrow ACCON-NetLink-WLAN
ACCON-NetLink-WLAN

The new edition of the proven ACCON-NetLink-PRO

ACCON-NetLink-WLAN is the further development of the proven communication and programming adaptor ACCON-NetLink-PRO between PC and S7 PLCs. In addition to the communication via a wired Ethernet network (LAN), this adaptor even supports the communication via a wireless Ethernet network (Wireless LAN).
As all-rounder, the ACCON-NetLink-WLAN can be connected to the PLC via MPI, PROFIBUS and PPI. The bus connector has electronics that separates the ACCON-NetLink-WLAN’s connection cable from the bus (MPI, PROFIBUS, PPI) so that there are no spur lines. The ACCON-NetLink-WLAN independently detects the current bus settings of the PLC.
The communication of the ACCON-NetLink-WLAN to the PC is effected via TCP/IP. The configuration of the ACCON-NetLink-WLAN can be made and changed via its integrated website. For the security of you facility, the access to the website is protected by a password.
The ACCON-NetLink-WLAN even supports the S7 communication via RFC 1006 (ISO on TCP). Thus, the ACCON-NetLink-WLAN can be activated like a TCP/IP communication processor (e.g. CP343-1). However, projected connections are not supported.
The ACCON-NetLink-WLAN supports the parameterization of DP slaves via DP-V1 (class 2).
A driver for SIMATIC applications (ACCON-S7-NET) is included in delivery.
The ACCON-NetLink-WLAN is normally fed by the connected bus. Alternatively, you can use external 24 VDC.

Perfect fields of application
As programming adaptor to create or change the PLC program
As communication adaptor for visualizations
As communication adaptor for accessing the PLC’s data

Varied ranges of application
Programming S7 controllers with STEP 7
Changing S7 programs via the company network (intranet)
Projecting HMI devices with WinCC flexible
Connecting visualizations to S7 controllers via TCP/IP (RFC 1006)
Logging S7 data via TCP/IP (e.g. with ACCON-S7-EasyLog)

Convincing and varied
Functionally, the ACCON-NetLink-WLAN equals the proven and varied communication and programming adaptor ACCON-NetLink-PRO, but in addition it can communicate via WLAN, as well.

Technical highlights
Optionally accessing via WLAN or Ethernet possible
Operating possible either with or without WLAN access point
Supporting MPI, PROFIBUS and PPI
Full PROFIBUS speed up to 12 Mbps
Supporting ISO on TCP (RFC 1006)
Voltage supply from the CPU
External 24 VDC voltage feed possible
Supporting all standard SIMATIC Engineering Tools

Order data

 

ACCON-NetLink-WLAN

ACCON-NetLink-WLAN
€649,00
Add to Cart
  

Accessories
Top-hat rail bracket long
External power supply 24 VDC for S7 adaptors
2.4 GHz magnet base antenna

Technical data

Supported operating systemsNo limitations (the driver for SIMATIC ACCON-S7-NET is only for Windows 2000, XP, 2003, Vista, 7, 2008)
Hardware requirementsWLAN or Ethernet interface and TCP/IP protocol
Supported PLCsS7-200, S7-300, S7-400
Weight in kgCa. 0.28
Dimensions (W x H x D) in mm68 x 133 x 30
Protection typeIP 20
Supply voltage24 VDC ± 25 %
External voltage feed possibleYes
Power consumptionMax. 200 mA
Galvanically isolatedYes
Operating temperature0 °C to 60 °C
Storage/transporting temperature-20 °C to 90 °C
Allowed relative humidity5 % to 85 % at 30 °C (no bedewing)
Connection cable to the PLCStationary mounted, active (no spur line, 1.2 m)
Connection cable to the PCPatch cable (Ethernet, straight, 3 m)
Supported bus systemsPROFIBUS, MPI, PPI
Supported bus profilesMPI and PROFIBUS (DP, Standard, Universal (DP/FMS), User-Defined) both fixed and even with automatic detection of the bus parameter, PPI
Supported transmission rates of the bus connection to the PLC9.6 Kbps to 12 Mbps with automatic detection
Supported transmission rates Ethernet10/100 Mbps with automatic detection
Antenna connection on boxRP-SMA bushing (external thread and pin)
WLAN standardIEEE 802.11b and 802.11g (2.4 GHz-Band, max. 54 Mbps)
Transmitting power14 dBm +1,5 dBm/-1,0 dBm
Wireless security methodsWEP, WPA, WPA2
Max. number of connections to TCP/IP16
Max. number of connections to MPI, PROFIBUS, PPI32
Supported softwareACCON-AGLink, ACCON-S7-EasyLog, DELTALOGIC S7/S5-OPC-Server, ACCON-S7-Backup, ACCON-NCK-Explorer.
With the driver for SIMATIC ACCON-S7-NET you can additionally use SIMATIC Manager from V5.3, WinCC 6.0, WinCC flexible, ProTool, STEP 7-Micro/WIN
 