News arrow Products arrow Software arrow ACCON-AGLink
ACCON-AGLink

The fast and flexible communication library

Conventional PLCs are often the standard solution for automation requirements. For control systems with an increased computing time or large data collectives, PCs and server are the first choice. The connection of both systems is ACCON-AGLink’s mission. The communication library ACCON-AGLink arranges for a smooth data exchange between PC and PLC. For this reason, manually created PC programs can simply access to a wide range of PLCs.
The existing software variety is a challenge for a networked workflow in automation and controlling engineering. Automation applications as controlling, monitoring, visualizing and filing are not possible before accessing to the PLCs’ process data. For this purpose, the applications need to speak the same »language« as the PLCs – meaning mastering their protocols. This is exactly the communication ACCON-AGLink has been developed and optimized for.
No matter if you access to the several data areas (D, I, Q, M, T, C, P), readout the diagnostic puffer of an S7-PLC or if you want to synchronize the PLC time with the PC time, ACCON-AGLink provides you with the appropriate prepared functions. For the further simplification, ACCON-AGLink contains a lot of conversion functions to turn PLC data types into PC data types.

Perfect fields of application
ACCON-AGLink is independent from the applied PLC-hardware: No matter which PLC-hardware you want to access to, with ACCON-AGLink you don’t have to care about the details. Therewith, you are even able to access to a vintage S5 or a new S7-1200 without any changes in your source code respectively in your application. With ACCON-AGLink, the access to the following PLCs are open to you:

  • S7-200, S7-1200, S7-300, S7-400, S7-400H
  • S7-compliant PLC, e.g. Vipa, Saia, Berthel
  • SINUMERIK 840D
  • S5
  • Devices with 3964/3964R protocol
  • Devices with RK512 protocol

Additionally, ACCON-AGLink is independent from the used communication channel: The different controller generations and PLC types are supporting the different communication channels – ACCON-AGLink as well. The following communication channels are at your disposal:

  • S7-TCP/IP for S7 via 243-1, 343-1, 443-1, PN- and IE-CPUs (even S7-1200)
  • MPI via ACCON-MPI-Adaptor USB, ACCON-MPI-Adaptor RS-232, ACCON-MPI/TS-Adaptor, ACCON-NetLink-PRO, ACCON-NetLink-WLAN, ACCON-NetLink-USB, ACCON-NetLink-USB compact, ACCON-NetLink-S7, Siemens-PROFIBUS-CP, PROFIBUS-Cards from Softing and Hilscher
  • PROFIBUS via ACCON-NetLink-PRO, ACCON-NetLink-WLAN, ACCON-NetLink-USB, ACCON-NetLink-USB compact, ACCON-NetLink-S7, Siemens-PROFIBUS-CP, PROFIBUS-cards from Softing and Hilscher
  • PPI via ACCON-PPI-Cable, ACCON-NetLink-PRO, ACCON-NetLink-WLAN, ACCON-NetLink-USB, ACCON-NetLink-USB compact, ACCON-NetLink-S7, Siemens-PROFIBUS-CP, PROFIBUS-cards from Softing and Hilscher
  • TeleService via modem to ACCON-MPI/TS-Adapter, ACCON-MPI-Modem, ACCON-MPI/PROFIBUS-Modem, Alarm Modem
  • S5-TCP/IP for S5 via CP 1430 TCP, Inat S5-TCP/IP 100, Vipa CP 143 TCP/IP, ACCON-S5-LAN
  • AS511 via ACCON-COM-Cable, ACCON-COM-Cable USB, ACCON-COM-Cable IE, ACCON-S5-LAN
  • RK512 via serial interface
  • 3964 and 3964R via serial interface

ACCON-AGLink is also independent from the used operating system. You want to write your application independently from the operating system? Then, you have chosen the right communication library with ACCON-AGLink. The change from a standard desktop application to a WinCE panel application often needs only a new compiling for the target system. ACCON-AGLink is available for the following operating systems:

  • Windows 2000, XP, Server 2003, Vista, Server 2008, 7, CE (starting from version 4)
  • Linux
  • Solaris
  • OS9000

Finally, ACCON-AGLink is independent from the used programming language as well: No matter if you have your personally preferred programming language or if you choose your programming language appropriately to the project requirements – ACCON-AGLink supports a variety of development environments. You are free to choose from the following list:

  • Microsoft Visual C/C++, Microsoft Visual Basic, Microsoft C#, Microsoft VB.net
  • Borland Delphi, C++ Builder
  • Codegear Delphi, C++ Builder
  • Embarcadero Delphi, Delphi Prism, C++ Builder
  • LabVIEW
  • Java
  • All languages being able to use a Win32- respectively WinCE-DLL
  • Gcc for Linux

Varied ranges of application
ACCON-AGLink includes sample programs for the majority of programming languages. But this was not enough for us. Therefore, we have developed the API-Guide (API = Application Programming Interface) for you. With this software, you can not only execute and test every single function of ACCON-AGLink directly and interactively, but also view the respective source code in C#, VB.net, C++, Delphi and Java. So, your entries will directly be translated in the program code. Then, you can immediately copy it and paste it in your development environment. There is no faster way to develop the communication section.
ACCON-AGLink can even directly access to the symbols used in the PLC project. You want to select the operands from the symbols used in the PLC project in your application? You don’t want to keep »M 10.0« in mind but you prefer to use »rear door contact«? Very good, because thus a potential error source is eliminated.
With ACCON-AGLink, you can access to the symbolic data in the following programs:

  • S7-300-, S7-400 programs

Convincing and varied
As a feature, ACCON-AGLink offers the possibility to react to PLC telegrams in an event-driven way in order to not having to start steady scans. So, BRECEIVE, URECEIVE, the complete alert and confirmation handling as well as the operating status change-over messages are available with ACCON-AGLink.
Or do you want the PLC to send you only cyclic defined values without having to ask every time? Even these functions have been implemented for you.
Complex control systems with different network technologies are no more problem with ACCON-AGLink as well because they can easily use the S7-PLC’s routing connections (e. g. from Ethernet to PROFIBUS). And this is of course possible without needing to change any line of your program.
Do you want to access to more than one PLC at the same time? The quantity structure of ACCON-AGLink leaves nothing to be desired: Up to 256 communication devices with up to 16 PLCs each should be enough for each case. Thereby, the devices can be different of course – even a parallel access to the most different controller generations is easily manageable.

Technical highlights
Supporting S7-200, S7-1200, S7-300, S7-400, S7-400H and S5 PLCs
Supporting routed, configured and redundant connections
Communication via MPI, PROFIBUS, PPI, TCP/IP and RK512/3964(R)
Integrated teleservice functionality
Possibility to change the communication channel without changing the program
Uniform software for all types of controllers and all supported operating systems
Comprehensive functionality to write and read process data
Comprehensive comfort functions
Access to S7 symbol table
Available for Windows, Windows CE, Linux, Solaris and OS9000
Supporting all current programming languages via DLL or shared object
Maintenance contract obtainable

You have the choice
The software ACCON-AGLink is available as single licence or as developer licence.
The ACCON-AGLink single licence always contains all available ACCON-AGLink modules. The single licence must be purchased for each PC on which ACCON-AGLink is used. You don’t need to look to the used communication hardware or controller; with the ACCON-AGLink single licence you always have the complete package.
Alternatively, you can purchase the developer licence. This can consist of any combination of the available ACCON-AGLink modules. Each developer needs his own ACCON-AGLink licence. Subject to our licence terms, the developer licence contains an unlimited number of runtime licences. Additionally, a maintenance contract is obtainable for the developer licence. This contains of the Software-Update-Service (SUS) and the Premium Support. Within the SUS, during the runtime of your maintenance contract, you gain all ACCON-AGLink updates immediately via e-mail. Thus, you are also up to date on firmware changes or new types of CPUs.

Order Data

ACCON-AGLink single licence USB

ACCON-AGLink single licence USB
€510,00
Add to Cart
ACCON-AGLink single licence

ACCON-AGLink single licence
€510,00
Add to Cart
ACCON-AGLink S7-TCP/IP developer licence Win32

ACCON-AGLink S7-TCP/IP developer licence Win32
€3.000,00
Add to Cart
 
ACCON-AGLink S7-PB developer licence Win32

ACCON-AGLink S7-PB developer licence Win32
€1.500,00
Add to Cart
ACCON-AGLink S7-PC/CP developer licence Win32

ACCON-AGLink S7-PC/CP developer licence Win32
€3.000,00
Add to Cart
ACCON-AGLink S7-serial developer licence Win32

ACCON-AGLink S7-serial developer licence Win32
€1.500,00
Add to Cart
 
ACCON-AGLink S5-TCP/IP developer licence Win32

ACCON-AGLink S5-TCP/IP developer licence Win32
€1.500,00
Add to Cart
ACCON-AGLink S5-AS511 developer licence Win32

ACCON-AGLink S5-AS511 developer licence Win32
€1.500,00
Add to Cart
ACCON-AGLink RK512 developer licence Win32

ACCON-AGLink RK512 developer licence Win32
€1.500,00
Add to Cart
 
ACCON-AGLink S7-SymbolikPro developer licence Win32

ACCON-AGLink S7-SymbolikPro developer licence Win32
€3.000,00
Add to Cart
  

The developer licences for Linux and Windows CE are not listed for clearness reasons. Our technical sales department is pleased to send you an appropriate offer.

Accessories
ACCON-NetLink-PRO
ACCON-S5-LAN

Technical data

Supported operating systemsWindows 2000, XP, 2003, Vista, 2008, 7, Windows CE (V4 and above), Linux, Solaris, OS9000
Supported PLCsS5, S7-200, S7-1200, S7-300, S7-400, S7-400H (S7 compliant PLCs, e.g. Vipa, Saia, Berthel), devices with RK512 protocol

Supported communication channels

You can learn from the following table which controller is supported by ACCON-AGLink via which communication channel with which communication hardware.

PLC interfacePC interface
TCP/IPUSBRS-232Siemens CP
S7-300/400/400H via MPIACCON-NetLink-PRO
ACCON-NetLink-WLAN
ACCON-NetLink-S7
ACCON-NetLink-USB
ACCON-NetLink-USB compact
ACCON-MPI-Adapter USB
ACCON-MPI-Adapter RS-232
ACCON-MPI/TS-Adapter
+
S7-300/400/400H via PROFIBUSACCON-NetLink-PRO
ACCON-NetLink-WLAN
ACCON-NetLink-S7
ACCON-NetLink-USB
ACCON-NetLink-USB compact
-+
S7-300/400/400H via TCP/IP (PN/IE)+--+
S7-300/400/400H via modem--ACCON-MPI/PROFIBUS-Modem
ACCON-MPI-Modem
ACCON-MPI/TS-Adapter
Alarm Modem
-
S7-200 via PPIACCON-NetLink-PRO
ACCON-NetLink-WLAN
ACCON-NetLink-S7
ACCON-NetLink-USB
ACCON-NetLink-USB compact
ACCON-PPI-Adapter+
S7-200 via TCP/IP+--+
S7-1200 via TCP/IP+--+
S5 via PG bushing (AS511)ACCON-COM-Kabel IE
ACCON-S5-LAN
ACCON-COM-Kabel USBACCON-COM-Kabel
ACCON-COM-Adapter
-
S5 via TCP/IP+---
3964/3964R/RK512--+-

+ Possible without any adaptor
- Not possible

Available ACCON-AGLink modules
ACCON-AGLink is structured modularly. You can learn from the following table which ACCON-AGLink module supports which communication hardware to access to which PLC interface.

ACCON-AGLink moduleSupported communication hardwareSupported PLC interfaces
ACCON-AGLink S7-seriellACCON-MPI-Adapter RS-232
ACCON-MPI-Adapter USB
ACCON-PPI-Adapter
MPI
PPI
ACCON-AGLink S7-seriell/TSACCON-MPI-Adapter RS-232
ACCON-MPI-Adapter USB
ACCON-PPI-Adapter
and via modem to ACCON-MPI/TS-Adapter
ACCON-MPI-Modem
ACCON-MPI/PROFIBUS-Modem
Alarm Modem
MPI
PROFIBUS
PPI
ACCON-AGLink S7-PBACCON-NetLink-PRO
ACCON-NetLink-WLAN
ACCON-NetLink-S7
ACCON-NetLink-USB
ACCON-NetLink-USB compact
Hilscher PROFIBUS cards
Softing PROFIBUS cards
MPI
PROFIBUS
PPI
ACCON-AGLink S7-TCP/IPNetwork interface card of the PCCP 243-1
CP 343-1
CP 443-1
PN and IE CPUs (even S7-1200)
ACCON-AGLink S7-PC/CPSiemens CPs via the Siemens device driver in »Set PG/PC interface« (CP 5511, CP 5512, CP 5611, CP 5613, CP 5614, CP 5711, CP 1613) and PC Adapter USBMPI
PROFIBUS
PPI
IE
ACCON-AGLink S7-RedConnIs only responsible for the redundancy, needs at least one further ACCON-AGLink communication module for the communicationDepends on the communication module
ACCON-AGLink S5-AS511ACCON-COM-Kabel
ACCON-COM-Kabel USB
ACCON-COM-Kabel IE
ACCON-S5-LAN
PG bushing of the S5
ACCON-AGLink S5-TCP/IPNetwork interface card of the PCCP 1430 TCP
Inat S5-TCP/IP 100
Vipa CP 143 TCP/IP
ACCON-S5-LAN
ACCON-AGLink RK512Serial cablee.g. CP 524 or CP 525
ACCON-AGLink S7-SymbolikProNone, allows the access to the symbolic operands of a S7-300 respectively S7-400 project-
 

Advanced Search
Show Cart