Variable programming adaptor with USB connection With the ACCON-NetLink-USB, a further powerful communication and programming adaptor between PC and S7 controllers is provided. The ACCON-NetLink-USB can be connected to the PLC via MPI, PROFIBUS and PPI. It independently detects the current bus settings of the PLC. The connection cable of the ACCON-NetLink-USB to the bus (MPI, PROFIBUS or PPI) is actively conducted. Therefore, there are no spur lines. Perfect fields of application As programming adaptor to create or change the PLC program As communication adaptor for visualizations As communication adaptor for accessing the PLC’s data Varied ranges of application Programming S7 controllers with STEP 7 Projecting HMI devices with WinCC flexible Logging S7 data (e.g. with ACCON-S7-EasyLog) Convincing and varied The communication of the ACCON-NetLink-USB to the PC is effected via USB. It supports the parameterization of DP slaves via DP-V1 (class 2). A driver for SIMATIC applications (ACCON-S7-NET) is included in delivery. The ACCON-NetLink-USB is normally fed by the PC via the USB connector. Alternatively, you can use external 24 VDC. Technical highlights Automatic bus profile detection Full PROFIBUS speed up to 12 Mbps USB 2.0 with up to 480 Mbps (high speed) Extended diagnostics Supporting MPI, PROFIBUS and PPI Supporting slave parameterization via DP-V1 (class 2) Supporting all standard SIMATIC Engineering Tools Active connection cable, therefore no spur lines Voltage supply via USB External 24 VDC voltage feed possible Plug with PG bushing Galvanically isolated Applicable up to 60°C Order data Accessories Top-hat rail bracket short External power supply 24 VDC for S7 adaptors Technical data | Supported operating systems | No limitations (the driver for SIMATIC ACCON-S7-NET is only for Windows 2000, XP, 2003, Vista) | | Hardware requirements | USB interface | | Supported PLCs | S7-200, S7-300, S7-400 | | Weight in kg | Ca. 0.25 | | Dimensions (W x H x D) in mm | 54 x 105 x 30 | | Protection type | IP 20 | | Supply voltage | Via USB or externally with 24 VDC ± 25 % | | External voltage feed possible | Yes | | Power consumption | Via USB 500 mA or externally max. 150 mA | | Galvanically isolated | Yes | | Operating temperature | 0 °C to 60 °C | | Storage/transporting temperature | -20 °C to 90 °C | | Allowed relative humidity | Operation 5 % to 85 % at 30 °C, storage 5 % to 93 % at 40 °C | | Connection cable to the PLC | Stationary mounted, active (no spur line, 1.2 m) | | Connection cable to the PC | USB cable (3 m) | | Supported bus systems | PROFIBUS, MPI, PPI | | Supported bus profiles | MPI and PROFIBUS (DP, Standard, Universal (DP/FMS), User-Defined) both fixed and even with automatic detection of the bus parameter, PPI | | Supported transmission rates of the bus connection to the PLC | 9.6 Kbps up to 12 Mbps with automatic detection | | Supported transmission rates USB | 12 Mbps (USB 1.1) and 480 Mbps (USB 2.0) | | Max. number of connections to MPI, PROFIBUS, PPI | 12 | | Supported software | ACCON-AGLink, ACCON-S7-EasyLog, DELTALOGIC S7/S5-OPC-Server, ACCON-S7-Backup, ACCON-NCK-Explorer. With the driver for SIMATIC ACCON-S7-NET you can additionally use SIMATIC Manager from V5.3, WinCC 6.0, WinCC flexible, ProTool, STEP 7-Micro/WIN |
|