VPN Router ECR-EW300
- 2x Ethernet and 2x2 digital I/Os
- WiFi access point and client
- 1x serial RS232 and 1x serial RS485
- Flexible mounting
- Sleep mode for energy self-sufficient applications
All-purpose with universal mounting options
The routers of the ECR series provide all important interfaces for realising extensive applications from remote services to IIoT. Both, the LAN and the LTE variant provide Wi-Fi for an operation as access point for local connection or as client for integration into an IT infrastructure. The LTE version offers cellular redundancy via dual SIM and fall-back to HSPA and GSM. The ECR is also suitable for an easy retrofit of existing plants due to its interfaces RS232 and RS485. The integrated digital I/Os extend the range of applications additionally. This VPN router can be mounted universally like the SCR and suitable for both, switch cabinets and small distribution boxes.
The icom SmartBox, an integrated Linux environment that enables to execute scripts and programs directly on the router, is also included besides the INSYS operating system icom OS.
With this, an ECR router can not only be used for secure remote maintenance and control, but also for acquiring and processing application data within the scope of edge computing. Amongst other things, this permits to monitor the conditions and values of connected devices as well as realise applications like reporting or benchmarking across different plants thanks to a plug & play connection to cloud services.
You do not want to set up your router yourself for our DELTA LOGIC Connectivity Service? No problem. We will gladly configure your new router for you. Just send us the completed form for the router configuration with the order.
Wi-Fi | |
Standard | IEEE 802.11 b/g/n |
Frequency, transmission power | 2,4 GHz, max. 100 mW |
WLAN (Wi-Fi) modes | WLAN (Wi-Fi) Station (Client) or WLAN (Wi-Fi) Access Point with up to 10 stations simultaneously |
Security | WPA/WPA2 (AES, TKIP), 802.1x (EAP: TLS, TTLS, PEAP) |
Antenna connection | Reverse SMA male |
Hardware interfaces | |
Ethernet ports | 2 x RJ45 shielded, 10/100 Mbit/s, full/half-duplex, auto MDI-X, 1.5 kV isolation voltage |
Ethernet function | Assignment to IP network freely configurable per port, link up/down detection |
I/Os | 2 digital inputs, high-active (as per EN 61131-2, Type 1) 2 open drain outputs (24 V/100 mA) |
RS232 (serial1) | 1 x RS232 / D-Sub-9 (m) |
RS485 (serial2) | Push-in terminal connector (D+, D-, GND) |
Functions of serial interface | Serial-Ethernet gateway (incoming and outgoing connections, Modbus TCP/RTU gateway, modem emulation, editable AT answer list, phone number conversion to IP addresses) |
Signal LEDs | Power, WAN (Internet connection) |
Network | |
Network functions | 100 local IP networks, IP static/DHCP, TCP, UDP, IPv4, IPv6, NTP, DHCP, DNS, HTTP/S, ARP, SSH, 802.1Q VLAN incl. tags and trunk ports |
Service | DHCP Server v4/v6 per IP network, DHCP relay, NTP server, DNS, DynDNS, IPv6 Router Advertiser |
Routing | Static routing, routing priority, RSTP, dynamic routing (OSPF, BGP, RIPv1, RIPv2, RIPng) |
WAN redundancy/failover | Several WAN connections configurable also in parallel operation, fallback level for connection breakdown (failover), event-based WAN changeover (see events) |
Connection check | Periodic, ping/icmp, DNS request, link up/down |
DSL | PPPoE for external DSL modems |
NAT/PAT | SNAT/DNAT (masquerade, netmapping, port forwarding, IP forwarding) unlimited number of rules |
VPN | |
DELTA LOGIC Connectivity Service | Supports VPN service for remote maintenance, remote access and M2M-communication |
OpenVPN | Client/Server, several parallel tunnels, server with up to 20 clients, tls-auth/tls-crypt, dead peer detection (DPD) |
OpenVPN encryption | DES EDE 128, DES EDE3 192, AES 128-256 CBC/GCM, SHA 256-512 |
IPsec | IKEv1, IKEv2 (automatic, fix), several parallel tunnels, pre-shared keys, certificates, tunnel mode, transport mode, dead peer detection (DPD) |
IPsec encryption | DES EDE3 192, AES 128-256 CBC/GCM, SHA 256-512 DH-Group 1-31 (Diffie-Hellman 768 - 25519), ChaCha20-Poly1305 |
GRE | GRE via IPsec, point-to-point, multipoint |
PPTP | PPTP client/server; PAP/CHAP/MS CHAP/MS CHAP V2; MPPE 40-128 |
Dynamic VPN | Dynamic multipoint VPN (GRE, IPsec, NHRP, EIGRP, OSPF, RIPv1/v2, BGP) |
IT security | |
Authentication | Pre-shared key, X.509 certificates, RADIUS, access rights (read, write, status) |
Firewall/netfilter | IP filters (stateful firewall) also in VPN tunnel; packet filter: TCP, UDP, ICMP, ESP, AP, GRE; MAC filter; pre-defined firewall rules can be activated |
Security | Booting signed firmware, HTTP/HTTPS attack prevention; response upon events: configuration change, link up/down, restart, login attempt, netfilter violation, password hashing |
IoT and Cloud (icom Data Suite, license required) | |
Function icom Data Suite | Machine connection and data processing; connection to cloud and SCADA Systems; arithmetic & logic functions; data logger; dashboard |
Data acquisition | CODESYS, Modbus TCP/RTU, MQTT, Siemens S7, OPC UA Client, IEC 60870-5-101, digital input, analog input |
Data transmission | MQTT, OPC UA Server, IEC 60870-5-104, Modbus TCP/RTU, e-mail, SMS, SFTP, digital input, analog input |
IoT platforms | MQTT compatibility: Thingsboard, Cumulocity, AnyViz, Azure IoT Hub, Bosch IoT Suite, AWS IoT Core |
Events & Actions | |
Event & Action Handler | Notification, alarming, diagnosis, attack detection, fault handling, operation and commissioning logic |
Events/alarms (selection) | Change: digital input, Ethernet port, WAN chain, profile status, cellular field strength; timer expired, firewall violation, login attempt detection, pulse sequence on digital input, counter, netfilter rule |
Event-triggered (selection) | Messages via e-mail, SMS (only LTE variants), SNMP traps, MCIP; switch profile, switch connection, change modem state, start timer, switch output or pulse sequence, activate firmware, reset, restart container |
Programming environment/scripting | |
Container environment | Installation of several application containers, container with own IP end point, assignment to IP networks - full firewall and routing transparency; access control, SDK available |
Container Ressources | CPU: 50% of ARMv7 (600 MHz), RAM: 448 MB, Flash: 1 GB eMMC |
Lua scripting | Lua interpreter for own scripts |
Monitoring and Management | |
Monitoring | SNMP traps and agent, configurable system logs, remote syslog, link up/down detection, netfilter violation |
Certificate management | EST, CRL |
Administration | |
Configuration | Web Interface HTTP(S) with session management, command line interface (CLI), Telnet, SSH, configuration profiles as ASCII and binary file, ample configuration profiles event-triggered, REST API |
Diagnosis tools | ping/icmp, tcpdump, traceroute, DNS Lookup, AT commands, port mirroring |
FW update | Incremental, failsafe, update server (HTTP, FTP, HTTPS, FTPS) |
System time | NTP client and server |
Help | Web interface: inline help, online help; example profiles, plausibility check, Configuration Guides |
Supply | |
Voltage | 12 ... 24 V DC (± 20% 9,6-28,8 V), reverse-polarity protected |
Terminals | 2-pin terminal connectors, rigid/flexible conductors up to 1,5 mm2 |
Power consumption | typical approx. 2.5 W, max. 4.0 W Sleep mode: typical approx. 65 mW |
Sleep mode | Sleep mode: Energy conservation mode with event-triggered activation, stopping via timer, reset, re-establishing supply or state change of digital input |
Ambient conditions | |
Dimensions (WxHxD) | 42 x 95 x 105 mm |
Weight | 290 g |
Mounting | DIN rail mounting and wall mounting horizontal pitch (HP) on DIN rail: 2.5 units (control cabinet) or 6 units (small distributor) |
Operating temperature | -30...+75 °C +70...+75 °C extended temperature range (refer to www.insys-icom.com/en/extended-temperature-range/) |
Humidity | 0...95% (non-condensing) |
Protection class | Housing: IP40 |
Approvals & Standards | |
Certifications | CE, UKCA |
EMV | Emission: EN 55032 Class B, EN 61000-6-3; Immunity: EN 55035 (ersetzt EN 55024), EN 61000-6-2 |
Safety | IEC/EN 62368-1 |
Environmental conditions | Tests Vibration and mechanic shock as per DIN EN 61131-2 und EN 60068-2-6, EN 60068-2-27; Temperature tests as per EN 60068-2-1, EN 60068-2-2, EN 60068-2-14, EN 60068-2-30 |
Operation time | MTBF > 770.000 h (25 °C), as per Standard SN 29500 (according to IEC 61709) |
Data sheet ECR series | ||
Data_sheet_ECR.pdf | 735 KB | December 19, 2024 |
Manual ECR | ||
Manual_ECR.pdf | 1.45 MB | December 19, 2024 |
Quick Installation Guide Router | ||
QIG_Router_en.pdf | 1.46 MB | December 12, 2023 |
DELTA LOGIC Connectivity Service First Steps | ||
DLCS_First_Steps.pdf | 122 KB | January 08, 2024 |