ACCON-S5-LAN
Communication adapter for the S5
- Compact connection of S5 PLCs to ethernet
- Quick and simple configuration and bringing into service
- Integrated multiplexer for simultaneous programming and visualization
- Access via virtual COM port
- Access via S5-TCP/IP (RFC 1006)
- Access via S7-TCP/IP (RFC 1006)
The pro for connections to S5 PLCs
ACCON-S5-LAN is a connection adapter between a PC and an S5 PLC via TCP/IP. It is fed by the PLC's interface. An external power supply is not necessary.Perfect fields of application
- As programming adapter to create and change the PLC program
- As communication adapter for visualizations
- As communication adapter to access the PLC's data
Varied ranges of application
- Programming an S5 PLC, e.g. with ACCON-PG or Siemens' STEP 5 software
- Visualising values of an S5 PLC with the DELTA LOGIC S7/S5-OPC Server via TCP/IP
Convincing and varied
In order to visualize and program simultaneously, the ACCON-S5-LAN has an integrated multiplexer.With the included software, a virtual serial interface can be installed on the PC. Each software supporting a serial connection to the S5 PLC can therefore use the ACCON-S5-LAN.
Furthermore, the ACCON-S5-LAN supports the S5-TCP/IP (RFC 1006) protocol as well as the S7-TCP/IP (RFC 1006) protocol. Thus, the ACCON-S5-LAN can be used with all programs supporting these protocols without additional drivers.
Technical highlights
- Compact connection of S5 PLCs to ethernet
- Quick and simple configuration and bringing into service
- Integrated multiplexer for simultaneous programming and visualization
- Access via virtual COM port
- Access via S5-TCP/IP (RFC 1006)
- Access via S7-TCP/IP (RFC 1006)
Supported operating systems |
No limitations |
Connection to the PC | RJ45 socket for Ethernet 10/100 Mbps with automatic detection, no cable included in delivery |
Connection to the PLC | TTY with 15-pin SUB-D plug |
Supported PLCs | S5 of the U series |
Dimensions (W x H x D) in mm | 42 x 15 x 65 |
Protection type | IP 20 |
Supply voltage | 24 VDC from PLC interface Not possible with AG 90 and AG 95, external power supply necessary, e.g. this external power supply |
External voltage feed possible | Yes |
Power consumption | Max. 80 mA |
Galvanically isolated | No |
Integrated multiplexer | Yes |
Software and user manual (in German) ACCON-S5-LAN | ||
ACCON-S5-LAN.zip | 6.43 MB | February 13, 2018 |
Data sheet | ||
Data_sheet_ACCON-S5-LAN.pdf | 636 KB | April 03, 2021 |
Hoja_de_datos_ACCON-S5-LAN.pdf | 633 KB |
April 03, 2021 |
Why can I not go online with my ACCON-S5-LAN even though I have entered the IP address correctly?
Please check if the correct server port is entered. The correct server port is 102.
Why is my ACCON-S5-LAN not found by the S5-LAN Manager?
The search function uses UDP port 65467. It may be necessary to create an inbound rule for UDP 65467 in the Windows Firewall.