ACCON-S5-LAN

Communication adapter for the S5

  • Compact connection of S5 PLCs to ethernet
  • Quick and simple configuration and bringing into service
  • Integrated multiplexer for simultaneous programming and visualization
  • Access via virtual COM port
  • Access via S5-TCP/IP (RFC 1006)
  • Access via S7-TCP/IP (RFC 1006)

€452.00*

Product number: 11800

The pro for connections to S5 PLCs

ACCON-S5-LAN is a connection adapter between a PC and an S5 PLC via TCP/IP. It is fed by the PLC's interface. An external power supply is not necessary.

Perfect fields of application

  • As programming adapter to create and change the PLC program
  • As communication adapter for visualizations
  • As communication adapter to access the PLC's data

Varied ranges of application

Convincing and varied

In order to visualize and program simultaneously, the ACCON-S5-LAN has an integrated multiplexer.
With the included software, a virtual serial interface can be installed on the PC. Each software supporting a serial connection to the S5 PLC can therefore use the ACCON-S5-LAN.
Furthermore, the ACCON-S5-LAN supports the S5-TCP/IP (RFC 1006) protocol as well as the S7-TCP/IP (RFC 1006) protocol. Thus, the ACCON-S5-LAN can be used with all programs supporting these protocols without additional drivers.

Technical highlights

  • Compact connection of S5 PLCs to ethernet
  • Quick and simple configuration and bringing into service
  • Integrated multiplexer for simultaneous programming and visualization
  • Access via virtual COM port
  • Access via S5-TCP/IP (RFC 1006)
  • Access via S7-TCP/IP (RFC 1006)
Supported operating systems

No limitations
The driver for a virtual serial interface is for Windows 98SE, Me, NT, 2000, XP, Vista, 7, 8, 8.1, 10 (32 bit and 64 bit)

Connection to the PC RJ45 socket for Ethernet 10/100 Mbps with automatic detection, no cable included in delivery
Connection to the PLC TTY with 15-pin SUB-D plug
Supported PLCs S5 of the U series
Dimensions (W x H x D) in mm 42 x 15 x 65
Protection type IP 20
Supply voltage 24 VDC from PLC interface
Not possible with AG 90 and AG 95, external power supply necessary, e.g. this external power supply
External voltage feed possible Yes
Power consumption Max. 80 mA
Galvanically isolated No
Integrated multiplexer Yes
Software and user manual (in German) ACCON-S5-LAN
ACCON-S5-LAN.zip 6.43 MB February 13, 2018
Data sheet
Data_sheet_ACCON-S5-LAN.pdf 636 KB April 03, 2021
Hoja_de_datos_ACCON-S5-LAN.pdf 633 KB

April 03, 2021

Why can I not go online with my ACCON-S5-LAN even though I have entered the IP address correctly?

Please check if the correct server port is entered. The correct server port is 102.


Why is my ACCON-S5-LAN not found by the S5-LAN Manager?

The search function uses UDP port 65467. It may be necessary to create an inbound rule for UDP 65467 in the Windows Firewall.