Adapters for PC-PLC Communication

IoT and Industry 4.0 make the connection and thus the communication between IT and OT indispensable nowadays. The exchange of data for analysis, optimization, as well as for the actual production is no longer imaginable without it. In automation, this means connecting PLCs and PCs.

However, not all controllers offer the option of plugging in a simple Ethernet cable and thus being able to access the PLC directly and quickly from the PC. S5 PLCs, some S7 models and SINUMERIK controllers require a special adapter for communication and also for programming them from the PC.

With the S5 and S7 communication adapters from DELTA LOGIC, you can use the appropriate adapter for your application depending on the available socket on your controller. In this way, you can easily use older controllers without major effort and without having to invest in a new PLC.

ACCON-NetLink-USB compact Our proven communication adapter with USB interface
The compact all-rounder ACCON-NetLink-USB compact is the compact communication and programming adapter between PC and S7 controllers. The electronics of the ACCON-NetLink-USB compact is located in the box of a PROFIBUS connector, therefore the adapter is very small and handy.As an all-rounder the ACCON-NetLink-USB compact can be connected to the PLC via MPI, PROFIBUS and PPI. The ACCON-NetLink-USB compact automatically detects the current bus settings of the PLC. Perfect fields of application As programming adapter to create and change the PLC program As communication adapter to access the PLC's data Varied ranges of application For programming S7 controllers with STEP 7 For projecting HMI devices with WinCC flexible Convincing and varied The ACCON-NetLink-USB compact communicates with the PC via USB. It is supplied with power by the PC via its USB connector.The ACCON-NetLink-USB compact supports the parameterization of DP slaves via DP-V1 (class 2).A driver for SIMATIC applications (ACCON-S7-NET) is included in the scope of the delivery. Technical highlights Automatic bus profile detection Voltage supply via USB PROFIBUS connector with PG socket ACCON-AGLink implemented Made in Germany
€419.62*
Tip
ACCON-NetLink-PRO compact The compact all-rounder. Our most popular communication adapter
The compact all-rounder among the programming adapters between PC and S7 PLCs ACCON-NetLink-PRO compact is a handy communication and programming adapter between PC and S7 controllers. The electronics of the ACCON-NetLink-PRO compact is placed in the case of a PROFIBUS connector. Thus, the adapter is very small and handy.As all-rounder, the ACCON-NetLink-PRO compact can be connected to the PLC via MPI, PROFIBUS and PPI. The ACCON-NetLink-PRO compact automatically detects the current bus settings of the PLC. Perfect fields of application As programming adapter to create and change the PLC program As communication adapter for visualisations As communication adapter to access the PLC's data For remote maintenance via internet, intranet, dial-in router Varied ranges of application Programming S7 controllers with STEP 7 Changing S7 programs via a company network (intranet) Projecting HMI devices with WinCC flexible Connecting visualisations to S7 PLCs via TCP/IP (RFC 1006) Logging S7 data via TCP/IP (e.g. with ACCON-EasyLog) Remote maintenance of S7 controllers via internet (VPN, e.g. via the DELTA LOGIC Connectivity Service) Convincing and varied The communication of the ACCON-NetLink-PRO compact to the PC is effected via TCP/IP so that it can be used for remote maintenance purposes via router, intranet and internet. The ACCON-NetLink-PRO compact can be configurated via its integrated website. For the security of your facility, the access to the website is protected by a password.The ACCON-NetLink-PRO compact supports the S7 communication via RFC 1006 (ISO on TCP). Thus, TCP/IP communication processors (e.g. CP343-1) can be replaced by this adapter. However, projected connections are not supported. Furthermore, the ACCON-NetLink-PRO compact supports the parameterization of DP-Slaves via DP-V1 (class 2).A driver for SIMATIC applications (ACCON-S7-NET) is included in delivery. The ACCON-NetLink-PRO compact is fed by the connected bus. Alternatively, you can use external 24 VDC (e.g. with this external power supply). Technical highlights Compact design Automatic bus profile detection Full PROFIBUS speed up to 12 Mbps Extended diagnostics Supporting MPI, PROFIBUS and PPI Supporting DHCP Supporting slave parameterization via DP-V1 (class 2) Supporting all standard SIMATIC Engineering Tools Supporting ISO on TCP (RFC 1006) Active connection cable, therefore no spur lines Voltage supply from the CPU External 24 VDC voltage feed possible Plug with PG bushing Galvanically isolated Applicable up to 60 ° ACCON-AGLink implemented Made in Germany
€512.50*
Tip
ACCON-S5-LAN Communication adapter for the S5
The pro for connections to S5 PLCs ACCON-S5-LAN is a connection adapter between a PC and an S5 PLC via TCP/IP. It is fed by the PLC's interface. An external power supply is not necessary. Perfect fields of application As programming adapter to create and change the PLC program As communication adapter for visualizations As communication adapter to access the PLC's data Varied ranges of application Programming an S5 PLC, e.g. with ACCON-PG or Siemens' STEP 5 software Visualising values of an S5 PLC with the DELTA LOGIC S7/S5-OPC Server via TCP/IP Convincing and varied In order to visualize and program simultaneously, the ACCON-S5-LAN has an integrated multiplexer.With the included software, a virtual serial interface can be installed on the PC. Each software supporting a serial connection to the S5 PLC can therefore use the ACCON-S5-LAN.Furthermore, the ACCON-S5-LAN supports the S5-TCP/IP (RFC 1006) protocol as well as the S7-TCP/IP (RFC 1006) protocol. Thus, the ACCON-S5-LAN can be used with all programs supporting these protocols without additional drivers. Technical highlights Compact connection of S5 PLCs to ethernet Quick and simple configuration and bringing into service Integrated multiplexer for simultaneous programming and visualization Access via virtual COM port Access via S5-TCP/IP (RFC 1006) Access via S7-TCP/IP (RFC 1006)
€452.00*
ACCON-MPI-Adapter RS-232
A S7 adapter for direct access The ACCON-MPI-Adapter allows the connection of a PC via its serial interface to the MPI interface of a S7 PLC. If you prefer to use the Ethernet interface instead of the serial interface of your PC, you can thereby use a higher transmission speed. For this we recommend the ACCON-NetLink-PRO compact. Perfect fields of application As programming adapter to create and change the PLC program As communication adapter for visualizations As communication adapter to access the PLC's data Varied ranges of application Programming S7 PLCs with STEP 7 Connecting visualizations with S7 PLCs Logging S7 data (e.g. with ACCON-EasyLog) Convincing and varied The ACCON-MPI-Adapter RS-232 uses the same communication protocol as the PC adapter. Thus, the ACCON-MPI-Adapter RS-232 can be used with any software supporting the PC adapter. Technical highlights Low-cost solution for programming and visualization Serial transmission rate up to 115.2 Kbps MPI speed up to 187.5 Kbps Voltage supply from the CPU External 24 VDC voltage feed possible Made in Germany Note:Starting with STEP 7 version 5.5 SP2, Siemens no longer supports serial COM ports under Windows 7 64-bit. The Siemens TIA Portal also no longer supports any COM ports - regardless of which operating system it is installed on! We will be happy to advise you about alternatives.
€364.76*
ACCON-COM-Cable USB 3m S5 adapter with USB connector
S5 adapter with USB connection The ACCON-COM-Cable USB is an adapter to connect a PC with an S5 PLC. It is fed via USB. Therefore, an external power supply is not necessary. Perfect fields of application As programming adapter to create and change the PLC program As communication adapter for visualizations As communication adapter to access the PLC's data Varied ranges of application Programming a S5 PLC, e.g. with ACCON-PG or the Siemens STEP 5 software, on a notebook without RS-232 interface Connecting visualizations to S5 PLCs Convincing and varied The included software creates a virtual serial interface. Each software supporting a serial connection to the S5 PLC can therefore use the ACCON-COM-Cable USB. Technical highlights Connection via USB No separate power supply necessary Even usable with STEP 5
€178.00*
ACCON-COM-Cable Inexpensive adapter for connecting a PC with an S5 controller
The low-cost S5 adapter The ACCON-COM-Cable is a low-cost adapter to connect a PC with a S5 PLC. The voltage supply is effected via the PLC interface, thus an external voltage feed is not necessary. Perfect fields of application As programming adapter to create and change the PLC program As communication adapter for visualizations As communication adapter to access the PLCs data files Varied ranges of application Programming a S5 controller e.g. with ACCON-PG or the Siemens' STEP 5 software Connecting visualizations with S5 controllers Technical highlights Connection to COM interface No separate voltage feed necessary
€57.50*